For Hong Kong, China

          H3C S5560 High Performance Ethernet Switch

          HomeProducts & TechnologyEnterprise ProductsSwitchesH3C S5560 High Performance Ethernet Switch
          H3C S5560-EI High Performance Ethernet Switch

          H3C S5560-EI is the latest development of Gigabit speed Layer 3 Ethernet switch. This powerful and highly secure series switch is built based on industry-leading high performance hardware architecture and H3C Comware V7 platform. It supports diversified services, high capacity GE access point as well as high density 10GE uplink, which meet the requirements for high density campus access and high performance aggregation.

          H3C S5560-EI Series Ethernet switch includes the following models:

          S5560-30S-EI: 24 10/100/1000BASE-T Ethernet ports, 4 10G/1G BASE-X SFP+ ports; 2 40G QSFP+ ports;

          S5560-54S-EI: 48 10/100/1000BASE-T Ethernet ports, 4 10G/1G BASE-X SFP+ ports; 2 40G QSFP+ ports;

          S5560-30C-EI: 24 10/100/1000BASE-T Ethernet ports, 4 10G/1G BASE-X SFP+ ports; 1 expansion slot; 2 fan module slots; 2 power module slots;

          S5560-34C-EI: 28 10/100/1000BASE-T Ethernet ports, 8 SFP (Combo) ports; 4 10G/1G BASE-X SFP + ports; 1 expansion slot; 2 fan module slots; 2 power module slots;

          S5560-54C-EI: 48 10/100/1000BASE-T Ethernet ports, 4 10G/1G BASE-X SFP+ ports; 1 expansion slot; 2 fan module slots; 2 power module slots;

          S5560-30C-PWR-EI: 24 10/100/1000BASE-T Ethernet ports, 4 10G/1G BASE-X SFP+ ports; 1 expansion slot; 2 fan module slots; 2 power module slots;

          S5560-54C-PWR-EI: 48 10/100/1000BASE-T Ethernet ports, 4 10G/1G BASE-X SFP+ ports; 1 expansion slot; 2 fan module slots; 2 power module slots;

          S5560-30F-EI: 24 SFP ports; 8 10/100/1000BASE-T Ethernet (Combo) ports; 4 10G/1G BASE-X SFP+ ports; 1 expansion slot; 2 fan module slots; 2 power module slots;

          S5560-54QS-EI: 48 10/100/1000BASE-T Ethernet ports; 4 10G/1G BASE-X SFP+ ports; 2 40G QSFP+ ports; 2 fan module slots; 2 power module slots.

          High scalability and high port density

          S5560-EI has 4 fixed 10GE ports with expansion slots, supporting multiple types of interface cards: 2-port 10GBaseT / SFP+; 8-port 10GBaseT / SFP+ card; 2-port 40G QSFP+ card. The switch supports up to 12 10G ports or 2 40G ports. The scaling flexibility and the high port density satisfy the requirements for hybrid configuration of copper ports and fiber ports at the distribution layer in large sized networks or at the core layer in SMB sized networks.

          High-performance IPv4/IPv6 service capabilities

          The S5560-EI switch comes with IPv4/IPv6 dual-stack platform, which provides sophisticated IPv4/IPv6 solutions by supporting multiple tunnels, IPv4/IPv6 Layer 3 routing protocols, multicasting, and policy-based routing. The S5560-EI switch is a mature commercial IPv6 product that has passed the IPv6 network access certification of the Chinese Ministry of industry and Information Technology and the IPv6 Ready Phase Ii certification.

          Intelligent Resilient Framework 2 (IRF2)

          H3C S5560-EI switch series is pre-built with Intelligent Resilient Framework 2 (IRF2). IRF2 provides the following benefits:

          High scalability: With IRF2, plug-n-play device aggregation can be achieved by adding one or more switches into the IRF2 stack and enabling IRF2 stacking on the new device. New devices can be managed with a single IP, and upgraded at the same time to reduce network expansion cost.

          High reliability: The IRF2 patented 1:N backup technology allows each slave device in the IRF2 stack to serve as the backup of the master, creating control and data link redundancy, as well as uninterrupted layer-3 forwarding. This improves the reliability, avoids unplanned business downtime and serves to improve overall performance. When the master device fails, traffic remains uninterrupted.

          Load balancing: IRF2 supports cross-device link aggregation, upstream and downstream can be connected to more than one physical link, which creates another layer of network redundancy and boosts the network resource utilization.

          Availability: H3C Implements IRF2 through standard Forty Gigabit Ethernet (40GE) or Ten Gigabit Ethernet (10GE) ports which allocates bandwidth for business and application access and reasonably splits local traffic and upstream traffic. IRF2 rules can not only be obeyed within and across the rack, but also across the LAN.

          Software Defined Network (SDN)

          Software Defined Network (SDN) is an innovative network architecture that simplifies network management and reduces maintenance complexity by separating network control layer and network forwarding layer through Openflow. More importantly, it implements flexible network flow control and provides a well-defined network platform for core network application and innovation.

          The S5560-EI network switch series supports a large network flow table. Combined with H3C SDN controller, it can easily implement a two-layer network architecture and quickly add functions in existing network in order to drastically reduces network management complexity while substantially lowers network maintenance cost.

          Support for multiple services

          The S5560-EI switch supports Multi-VRF and can operate as an MCE device. It supports Layer 3 MPLS VPN and Layer 2 MPLS VPN in Martini mode and Kompella mode. Working with the H3C MPLS VPN Manager, the switch can implement graphical MPLS deployment and maintenance. The switch also supports VPLS, providing end-to-end Layer 2 VPN access solutions and MPLS/VPLS wire-speed forwarding, satisfying large scaled VPLS deployment requirements.

          Multiple high availability measures

          The S5560-EI switch series supports high availability at device level and link level.

          The S5560-EI switch series adopts hot swappable dual-power supply and dual fan module design, which allows you to configure AC or DC power supplies as needed. The switch can detect faults in power supplies and fans, and will if any such faults are found, respond with an alarm. It can automatically adjust fan speed according to the temperature.

          Apart from device level redundancy, the S5560-EI series switch also provides diverse link redundancy support such as LACP/STP/RSTP/MSTP/Smart Link protocols. It supports IRF2 and 1: N redundancy backup as well as cross-device link aggregation which substantially increases network reliability.

          Abundant QoS policies

          The S5560-EI switch series supports packet filtering at Layer 2 through Layer 4, and traffic classification based on source MAC addresses, destination MAC addresses, source IP addresses, destination IP addresses, TCP/UDP port numbers, protocol types, and VLANs. It supports flexible queue scheduling algorithms based on ports and queues, including strict priority (SP), weighted round Robin (WRR), SP+WRR, weighted fair queuing (WFQ), and WDRR. The S5560-EI switch series enables committed access rate (CAR) with the minimum granularity of 8 kbps. It supports port mirroring in the outbound and inbound directions, to monitor the packets on the specific ports, and to mirror the packets to the monitor port for network detection and troubleshooting.

          Professional Anti-lighting function

          The S5560-EI switch series uses built-in lighting protection technology and supports industry leading switch port 6KV anti-lighting capability, which can greatly reduce the rate of lightning damage to the equipment.

          Enhanced PoE+ capability

          H3C S5560-EI switch series supports 802.3af/802.3at PoE function, single port can provide maximum 30w, providing power to connected devices, such as IP phones, wireless APs, and high power cameras. H3C S5560-EI switch series supports multiple PoE modules for flexible PoE output selections, single switch can provide total 1440W PoE power, 30w per port and total 48 ports PoE+ function.

          Excellent manageability

          The S5560-EI switch series supports abundant management ports, such as the console port, mini-USB and the out-of-band network management port. It supports the Simple Network Management Protocol (SNMP) v1/v2/v3, Open View, IMC, CLI, Web-based NMS and Telnet allowing easy device management. It also supports SSH2.0 to provide better protection management.

          The S5560-EI switch supports SPAN/RSPAN/ERSPAN mirroring, and multiple mirroring ports so that network traffic can be analyzed to carry out corresponding management and maintenance measures and traffic of network services and applications is visible. The S5500-HI switch provides network stream analysis reports, which help users to promptly optimize the network structure and adjust resource deployment.

          Feature

          S5560-

          30S-EI

          S5560-

          54S-EI

          S5560-

          30C-EI

          S5560-

          34C-EI

          S5560-

          54C-EI

          S5560-

          30F-EI

          S5560-

          30C-PWR

          -EI

          S5560-

          54C-PWR

          -EI

          S5560-

          54QS-EI

          Switching capacity

          598G

          Forwarding capacity

          216Mpps

          252Mpps

          216Mpps

          222Mpps

          252Mpps

          216Mpps

          216Mpps

          252Mpps

          252Mpps

          Dimensions (WxDxH)

          440×260

          ×43.6

          440×260

          ×43.6

          440×360

          ×43.6

          440x360

          X43.6

          440×360

          ×43.6

          440×360

          ×43.6

          440×460

          ×43.6

          440×460

          ×43.6

          440×260

          ×43.6

          Weight

          ≤5kg

          ≤5kg

          ≤5kg

          ≤5kg

          ≤5kg

          ≤5kg

          ≤10kg

          ≤10kg

          ≤5kg

          Out of band management

          0

          0

          1

          1

          1

          1

          1

          1

          2

          Management ports

          RJ-45 Console port, One Mini USB Console port (Mini USB first priority)

          Front panel data ports

          24 10/100/

          1000

          BASE-T Ethernet ports, 4 10G/1G BASE-X SFP+ ports, 2 40G QSFP+ ports

          48 10/100/1000

          BASE-T Ethernet ports, 4 10G/1G BASE-X SFP+ ports,2 40G QSFP+ ports

          24

          10/100/

          1000

          BASE-T Ethernet ports, 4 10G/1G BASE-X SFP+ ports

          28

          10/100/

          1000 BASE-T Ethernet ports; 8 SFP (Combo) ports, 4 10G/1G BASE-X SFP+ports

          48

          10/100/

          1000

          BASE-T Ethernet ports, 4 10G/1G BASE-X SFP+ ports

          24

          SFP ports, 8 10/100/

          1000

          BASE-T Ethernet (Combo) ports, 4 10G/1G BASE-X SFP+ ports

          24 10/100/1000BASE-T Ethernet ports, 4 10G/1G BASE-X SFP+ ports

          48

          10/100/

          1000

          BASE-T Ethernet ports, 4 10G/1G BASE-X SFP+ ports

          48 10/100/

          1000

          BASE-T Ethernet ports, 4 10G/1G BASE-X SFP+ ports, 2 40G QSFP+ ports

          Expansion slots

          0

          One

          0

          Interface card

          0

          2-port 40GE QSFP+ /2-port 10G SFP+ /2-port 10GBaseT /

          8-port 10G SFP+ /8-port 10G BaseT

          0

          SDN/

          Openflow

          OpenFlow 1.3

          Multiple controllers (EQUAL, master/slave)

          Multiple tables flow

          Group table

          Meter

          Port aggregation

          GE/10GE/40GE port aggregation

          Dynamic aggregation

          Static aggregation

          Cross-device aggregation

          Port features

          IEEE802.3x flow control (full duplex)

          Storm control based on port rate percentage

          PPS/BPS-based storm control

          Jumbo frame

          10000

          MAC table

          Blackhole MAC address

          Configurable maximum number of MAC addresses that can be learned by a port

          VLAN

          Port-based VLAN

          MAC-based VLAN

          Protocol-based VLAN

          Subnet-based VLAN

          QinQ and selective QinQ

          VLAN mapping

          Voice VLAN

          GVRP

          Layer 2 Ring Network Protocol

          STP/RSTP/MSTP

          RRPP

          Smart Link

          DHCP

          DHCP client

          DHCP snooping

          DHCP relay

          DHCP server

          DHCP snooping option82/DHCP Relay option82

          IRF2

          IRF2

          Distributed device management, distributed link aggregation, and distributed resilient routing

          Stacking through standard Ethernet interfaces

          Local device stacking and remote device stacking

          IP routing

          Static routing

          RIPv1/v2 and RIPng

          OSPFv1/v2 and OSPFv3

          BGP4 and BGP4+ for IPv6

          ECMP and policy-based routing

          VRRP/VRRPv3

          IPv6

          Neighbor discovery (ND)

          PMTU

          IPv6-Ping, IPv6-Tracert, IPv6-Telnet, and IPv6-TFTP

          Manual tunnel configuration

          6to4 tunnel

          ISATAP tunnel

          IPv6 in IPv6 tunnel

          IPv4 in IPv6 tunnel

          GRE tunnel

          Multicast

          IGMP snooping v1/v2/v3 and MLD Snooping v1/v2

          PIM snooping

          MLD proxy

          Multicast VLAN

          IGMP v1/v2/v3 and MLD v1/v2

          PIM-DM, PIM-SM, and PIM-SSM

          MSDP and MSDP for IPv6

          MBGP and MBGP for IPv6

          Mirroring

          Traffic mirroring

          N:4 port mirroring

          Local and remote port mirroring

          OAM

          802.1ag

          802.3ah

          ACL\QoS

          Packet filtering at Layer 2 through layer 4

          Traffic classification based on source MAC addresses, destination MAC addresses, source IPv4/IPv6 addresses,

          destination IPv4/IPv6 addresses, TCP/UDP port numbers, protocol types, and VLANs

          Time range-based ACL

          Bidirectional ACL

          VLAN-based ACL

          Port rate limit (receiving and transmitting)

          Packet redirection

          802.1p DSCP remarking

          Committed access rate (CAR)

          Eight output queues on each port, and 48 queues on the CPU port

          Flexible queue scheduling algorithms based on ports and queues, including SP, WRR, WFQ, SP+WRR, and WDRR

          WRED

          Security

          Hierarchical user management and password protection

          802.1X authentication, centralized MAC authentication

          Guest VLAN

          RADIUS authentication

          SSH 2.0

          Port isolation

          Port security

          Portal authentication

          EAD

          DHCP snooping and anti-fraud DHCP server

          Dynamic ARP inspection, preventing man-in-the-middle attacks and ARP DoS attacks

          BPDU guard and Root guard

          URPF, prevent source IP spoofing, viruses and attacks

          IP/Port/MAC binding

          Plaintext and MD5 authentication of OSPF and RIPv2 packets

          PKI

          CPU protection

          MACSec

          Management and Maintenance

          Loading and upgrading through XModem/FTP/TFTP

          Configuration through CLI, Telnet, and console port

          SNMPv1/v2/v3 and Web-based NMS

          Remote monitoring (RMON ) alarm, event, and history recording

          IMC NMS

          System log, alarming based on severities, and output of debugging information

          NTP

          Alarm for power supplies, fans, and temperature

          Ping and Tracert

          Virtual cable test (VCT)

          Device link detection protocol (DLDP)

          LLDP

          Loopback-detection

          Green power

          EEE(802.3az)

          Port auto Power down

          Port schedule down

          Input voltage

          Non PoE model input voltage:

          AC:Rated voltage range:100V~240V AC, 50/60Hz

          DC:Maximum voltage range -36V~-72V DC

          PoE model input voltage:

          360W AC: 100V~240V, 50Hz~60Hz

          720W AC: 100V~240V, 50Hz~60Hz

          1110W AC: 115V~240V, 50Hz~60Hz

          Power consumption (full configuration)

          AC:66W

          DC:68W

          AC:80W

          DC:82W

          Single

          AC:107W

          Single

          DC:108W

          Dual

          AC:111W

          Dual

          DC:115W

          Single AC:120W

          Single DC:123W

          Dual AC:146W

          Dual DC:133W

          Single AC:123W

          Single DC:123W

          Dual AC:127W

          Dual DC:130W

          Single AC:120W

          Single DC:123W

          Dual AC:146W

          Dual DC:133W

          AC:1000W (including 720W PoE)

          AC: 1800W (including 1440W PoE)

          Single AC:112W

          Single DC:112W

          Dual AC:116W

          Dual DC:120

          Operating

          Temperature

          0℃~45℃

          Operating relative humidity (non-condensing)

          5%~95%

          Are you an H3C partner? Log in to see additional resources.
          You can find excellent H3C partners, or you can become one of them to build a
          partnership with H3C and share success together.

                  游戏网赚